Features
The main features are:
1. With failure window diagnosis function (optional)
2. 12.4mm ultra-thin, compatible with dual-channel signal transmission, saving space;
3. High bandwidth and low insertion loss, suitable for all kinds of signals;
Technical data
Parameter | PHL-T5-L2-EX PHL-T5-L3-EX PHL-T5-L4-EX |
PHL-T5-G2-EX PHL-T5-G4-EX |
PHL-T24-L2-EX PHL-T24-L3-EX PHL-T24-L4-EX |
PHL-T24-G2-EX PHL-T24-G4-EX |
Rated operational voltage | 5VCD | 5VCD | 24VDC | 24VDC |
Maximum operating voltage Uc | 6VDC | 6VDC | 32VDC | 32VDC |
Rated operating current IL | 600mA | 600mA | 600mA | 600mA |
Via resistance | 1Ω/线 | 1Ω/wire | 1Ω/wire | 1Ω/wire |
Bandwidth (-0.5dB) | 10MHZ | 10MHZ | 10MHZ | 10MHZ |
Response time | 1ns | 1ns | 1ns | 1ns |
Leakage current | <10uA | <1uA | <10uA | <10uA |
Nominal discharge current In (8 / 20μs) | 10kA/wire | 10kA/wire | 10kA/wire | 10kA/wire |
The maximum discharge current Imax (8 / 20μs) | 20kA/wire | 20kA/wire | 20kA/wire | 20kA/wire |
Lightning surge current limp (10 / 350μs) | 2.5kA/wire | 2.5kA/wire | 2.5kA/wire | 2.5kA/wire |
Protection voltage Up line-to-line | 40V | 40V | 60V | 60V |
Protection voltage Up line to ground | 600V | 40V | 600V | 60V |
Temperature range | -40℃~+80℃ |
Relative humidity | 10%~95% |
External dimensions (length x width x height) | 90.0mm×12.4mm×77.5mm |
Connection | Screw wiring |
Maximum cross-sectional area of the wire | 2.5mm |
Cross section area of guide rail grounding wire | 4~6mm |
Installation method | DN35mm Rail |
Outline dimension diagram
Failure window diagnosis function
Security certificate
(2) The terminal can be connected with multi-strand copper wire with cross-sectional area of 0.2~2.5mm2 or single-strand copper wire with cross-sectional area of 0.2~4mm2 ;
(3)The length of wire stripping is about 5-8mm, which is locked by screws.
The PHL-T series universal model adopts the DIN35mm guide rail installation method, and the steps are as follows:
⑴Clamp the upper metal at the bottom of the instrument on the DIN rail;
⑵Push the metal part at the bottom of the instrument into the guide rail;
⑶Suggest using copper or steel rails.
Disassembly
Maintenance
(1) When using SPD, there must be reliable grounding;
(2) Before the SDP is electrified and debugged, it is necessary to check again whether the connection between the input and output terminals is correct;
(3) The products have undergone strict inspection and quality control before leaving the factory. If you find that the work is abnormal and suspect that the internal module is faulty, please contact the nearest agent or directly contact the technical support hotline in time;
(4) Within one year from the date of delivery, any product quality problems during normal use shall be repaired by Beijing Pinghe free of charge.