Overview
PHG-11TT-*8 series thermocouple input temperature converter can output the millivolt signal sent by the thermocouple (TC) at a ratio of 1:1.
This product needs to be powered independently, and the power supply, input and output terminals are isolated between each other.
"*" indicates the thermocouple input type, and the specific model is represented by a code (see "Input Signal Type and Range Table" for details).
Input signal types and measurement range | ||||
Code | TC model | Measurement range | Minimum range | Conversion accuracy |
1 | K | -200~1370℃ | 50℃ | 0.5℃/0.1% |
2 | S | -50~1760℃ | 500℃ | 1.5℃/0.1% |
3 | E | -140~1000℃ | 50℃ | 0.5℃/0.1% |
4 | J | -160~1200℃ | 50℃ | 0.5℃/0.1% |
5 | B | 250~1800℃ | 500℃ | 1.5℃/0.1% |
6 | T | -200~400℃ | 50℃ | 0.5℃/0.1% |
7 | R | -50~1760℃ | 500℃ | 1.5℃/0.1% |
8 | N | -200~1300℃ | 50℃ | 0.5℃/0.1% |
Specifications,model and code
Input | |
Input signal | K, S, E, J, B, T, R, N thermocouple signals (see "Input Signal Type and Range Table" for details) |
Signal range | The measuring range of the corresponding thermocouple is -5~60mV |
Output: | |
Output signal | Thermocouple 1:1 |
Supply voltage | 20-35VDC |
Power consumption | Current output <0.8W (when powered by 24V DC) |
LED indicator | Green: Power indicator |
Output accuracy | Please refer to the "Input Signal Type and Range Table" for details |
Response time | Reaching 90% of the final value within 300ms |
Temperature drift | 0.005%F.S/℃ |
Temperature parameters | Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃ |
Relative humidity | 10%~95% RH no condensation |
Dielectric strength | ≥2000VAC/min (between input/output/power supply) |
Insulation resistance | ≥100MΩ (500V DC)(between input/output/power supply) |
Electromagnetic compatibility | Comply with IEC61326-1 (GB/T 18268), IEC 61326-3-1 |
MTBF | 80000h |
Wire requirements | Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V |
Applicable field equipments | K. S, E, J, B, T, R, N TC sensors |