PHG-11TT-*8+

Surge protection type TC input temperature converter 

PHG-11TT-*8+  1 input 1 output

Input :TC signal

Output :1:1 millivolt signal

Request a Quote

PRODUCTS DETAILS

Overview

The   PHG-11TT-*8+ thermocouple input temperature converter with surge protection function can transmit the millivolt signal from thermocouple (TC) and output in 1: 1.

This product requires independent power supply, with isolated power supply, input, and output terminals.

"*" represents the input type of the thermocouple, and the specific model is represented by a code (see "Input Signal Type and Range Table" for details).

Input signal types and measurement range
Code TC model Measurement range Minimum range Conversion accuracy
1 K -200~1370℃ 50℃ 0.5℃/0.1%
2 S -50~1760℃ 500℃ 1.5℃/0.1%
3 E -140~1000℃ 50℃ 0.5℃/0.1%
4 J -160~1200℃ 50℃ 0.5℃/0.1%
5 B 250~1800℃ 500℃ 1.5℃/0.1%
6 T -200~400℃ 50℃ 0.5℃/0.1%
7 R -50~1760℃ 500℃ 1.5℃/0.1%
8 N -200~1300℃ 50℃ 0.5℃/0.1%

For example: one input and one output, thermocouple K (-200~1370C) input, one channel 1:1 output, 24V power supply, model: PHG-11TT-18

Specifications

Input
Input signal K, S, E, J, B, T, R, N thermocouple signals (see "Input Signal Type and Range Table" for details)
Signal range The measuring range of the corresponding thermocouple is -5~60mV.
Safety side output:
Output signal Thermocouple 1: 1
Surge protection features:
Nominal discharge current ln(8/20μs) 5kA
Voltage protection level Up(8/20μs): 60V(line to line)
Voltage protection level Up(8/20μs): 600V(line to ground)
According to standards GB/T18802.21-2016(equivalent to 1EC61643-21:2012)
Power consumption <0.8W (24VDC power supply, 20mA output)
LED indicator Green: Power indicator
Output accuracy Please refer to the "Input Signal Type and Range Table" for details
Response time Reaching 90% of the final value within 300ms
Temperature drift 0.005%F.S/℃
Temperature parameters Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃
Relative humidity 10%~95% RH no condensation
Insulation strength ≥2000VAC/min  (between input/output/power supply)
Insulation resistance 100MΩ(500V DC)   (between input/output/power supply)
Electromagnetic compatibility According to IEC 61326-1(GB/T 18268), IEC 61326-3-1
MTBF 80000h
Wire requirements Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V
Applicable field equipments K. S, E, J, B, T, R, N TC sensors
Installation place Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC

Dimension

PHG-11TT-x8+.jpg

 Schematic diagram

PHG-11TT-x8+(1).jpg

Note:

1. The power rail function is an optional function, and users need to specify the power supply method when placing an order

The selection of power rail connectors can refer to page 89 of the "Annex"

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

return