Overview
The thermocouple input isolation safety barrier can transmit the millivolt signal from thermocouple (TC) in the dangerous area to the safe area in 1: 1.
This product requires independent power supply, with isolated power supply, input, and output terminals.
"*" represents the input type of the thermocouple, and the specific model is represented by a code (see "Input Signal Type and Range Table" for details).
Input signal types and measurement range | ||||
Code | TC model | Measurement range | Minimum range | Conversion accuracy |
1 | K | -200~1370℃ | 50℃ | 0.5℃/0.1% |
2 | S | -50~1760℃ | 500℃ | 1.5℃/0.1% |
3 | E | -140~1000℃ | 50℃ | 0.5℃/0.1% |
4 | J | -160~1200℃ | 50℃ | 0.5℃/0.1% |
5 | B | 250~1800℃ | 500℃ | 1.5℃/0.1% |
6 | T | -200~400℃ | 50℃ | 0.5℃/0.1% |
7 | R | -50~1760℃ | 500℃ | 1.5℃/0.1% |
8 | N | -200~1300℃ | 50℃ | 0.5℃/0.1% |
Specifications
Input in harzadous area | |
Input signal | K, S, E, J, B, T, R, N thermocouple signals (see "Input Signal Type and Range Table" for details) |
Signal range | The measuring range of the corresponding thermocouple is -5~60mV. |
Safety side output: | |
Output signal | Thermocouple 1: 1 |
LED indicator | Green: Power indicator |
Output accuracy | Please refer to the "Input Signal Type and Range Table" for details |
Response time | Reaching 90% of the final value within 300ms |
Temperature drift | 0.005%F.S/℃ |
Temperature parameters | Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃ |
Relative humidity | 10%~95% RH no condensation |
Dielectric strength | Between intrinsically safe side and non-intrinsically safe side (≥ 3000VAC/min); between power supply and non-intrinsically safe terminal (≥ 1500VAC/min) |
Insulation resistance | ≥100MΩ (between input/output/power supply) |
Electromagnetic compatibility | According to IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
MTBF | 100000h |
Wire requirements | Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V |
Applicable field equipments | K. S, E, J, B, T, R, N TC sensors |
Installation place | Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC |
Dimension
Schematic diagram
Note:
1. The power rail function is an optional function, and users need to specify the power supply method when placing an order
The selection of power rail connectors can refer to page 89 of the "Annex"
Intrinsically safe certification
Functional safety certification | SIL3 according to IEC 61508 standards |
Explosion proof mark | [Ex ia Ga]lIC [Ex ia Da]lllC |
Explosion-proof standard | GB/T3836.1-2021 GB/T3836.4-2021 |
Terminals 3-4 | Um:250V AC/DC Uo=8.4V DC lo=31mA Po=65.1mW Co=4.8μF Lo=20mH |
Certification body | CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products) |