PHC-11TD-11+

Analogue Output Isolated Safety Barrier with surge protection function

 input and 1 output

Input: 4~20mA (HART digital signal)
Output: 4~20mA (HART digital signal)

Request a Quote

PRODUCTS DETAILS

Overview

The analog output isolated safety barrier with surge protection function can realize the isolated transmission of 4~20mA signals from the instruments in the safe area to the dangerous area, drive the valve positioner, electric/pneumatic converter and other equipment on site, and support the bidirectional transmission of HART digital signals with wirebreak alarm function. This product needs independent power supply, and the power supply, input and output are isolated.

Specifications

Input insafe area
Input signal  4~20mA (HART digital signal)
Output in dangerous area
Output signal 4~20 mA(HART  digital signal)
Load resistance When outputting 20mA, 0~500 Ω (customizable)
Nominal discharge current ln(8/20μs) 5kA
Voltage protection level Up(8/20μs): 60V(line to line)
Voltage protection level Up(8/20μs): 600V(line to ground)
According to standards GB/T18802.21-2016(equivalent to 1EC61643-21:2012)
Basic parameters
Supply voltage 20~35VDC
Power consumption ≤50mA(24V power supply, 20mA output)
LED indicator  Green: power indicator
Output accuracy 0.1%FS (Typical value: 0.05%F.S)
Response time 2ms to reach 90% of the final value
Temperature drift 0.005% F.S/℃
Temperature parameters Working temperature: -20℃ ~ +60℃,
Storage temperature: -40℃ ~ +80℃
Relative humidity 10%~95% RH no condensation
Insulation strength Between intrinsically safe side and non-intrinsically safe side (≥3000VAC/min); between power supply and non-intrinsically safe side (≥1500VAC/min)
Insulation resistance ≥100MΩ (between input/output/power supply)
Electromagnetic compatibility According to IEC 61326-1 (GB/T 18268), IEC 61326-3-1
MTBF 100000h
Wire requirements Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V
Applicable field equipments Valve locator, electric/pneumatic converter
Installation place Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC
Intrinsically safe certification
Explosion proof mark [Ex ia Ga]lIC [Ex ia Da]lllC
Explosion-proof standard GB/T3836.1-2021  GB/T3836.4-2021
Terminals 3-4 Um:250V AC/DC Uo=28V DC lo=93mA
Po=0.65W Co=0.083μF Lo=4.2mH
Certification body CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)
Shanghai lightning protection products testing center

 

Dimension 

PHC-11TD-11+.jpg

Schematic Drawings

PHC-11TD-11+(1).jpg

 

Note: 
1. The power supply of the power rail is an optional function. Users need to specify the power supply mode when ordering. Please refer to attachment on page 89.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

return