PH6404-2A2B

Applied in Safety Mats Input

Request a Quote

PRODUCTS DETAILS

Overview

PH6404-2A2B is a safety relay control module suitable for two wire safety mats inputs, with 2 normally open (NO) safety output contacts and 2 normally closed (NC) auxiliary output contacts for safety relays. It supports manual or automatic reset and has a reset button monitoring function.

 

Technical data

Power supply characteristics
Power supply  100~230V /AC
Power consumption ≤7VA (220V AC power supply, relay excitation state)
AC frequency 50Hz~60Hz
Input characteristics
Wire resistance ≤ 15 Ω
Input current ≤ 10mA (24V DC power supply)
Input device  Two wire safety mats
Terminator 2.0KΩ~20KΩ
Output characteristics
Number of contacts 2NO+2NC
Contact material  AgSnO2+0.2 μmAu
Contact type Forced guidance
Contact fuse protection  10A gL/gG, NEOZED (normally open contact)
6A gL/gG,NEOZED(normally closed contact)
Switching capacity(EN 60947-5-1) AC-15,5A/230V;DC-13,5A/24V
Mechanical lifespan  more than 107 times
Time characteristics
Switch-on delay  
Automatic reset ≤300ms
Manual reset ≤150ms
Delay-on de-energisation
Emergency stop operation ≤30ms
Power failure ≤300ms
Recovery time  ≤500ms
Supply short interruption  20ms

 

safety certification
Performance Level (PL) PLe                     conform to EN ISO 13849
Security Category (Cat.) Cat.4                   conform to EN ISO 13849
Task Time (TM) 20 years               conform to EN ISO 13849
Diagnostic coverage (DC/DCavg) 99%                     conform to EN ISO 13849
Safety Integrity Level (SIL) SIL3                     conform to IEC 61508,IEC 62061
Hardware Fault Tolerance(HFT) 1                          conform to IEC 61508,IEC 62061
Safe failure fraction(SFF)   99%                     conform to IEC 61508,IEC 62061
Probability of hazardous failure (PFHd)  3.09E-10/h           conform to IEC 61508,IEC 62061
StopCategory  0                          conforms to EN 60204-1
10% average number of hazardous failure cycles of components (B10d)
DC13,Ue=24V Ie                 5A               2A                         1A
Cycles          300,000        2,000,000               7,000,000
AC15,Ue=230V Ie                 5A                 2A                     1A
Cycles           200,000         230,000              380,000

 

Environmental characteristics
Electromagnetic compatibility conform to EN 60947,EN 61000-6-2,EN 61000-6-4
Vibration frequency  10Hz~55Hz
Vibration amplitude 0.35mm
Ambient temperature  -20 ℃~+60 ℃
Storage temperature  -40 ℃~+85 ℃
Relative humidity  10% to 90%
Altitude  ≤ 2000m
Insulation characteristics
Electrical clearance and creepage distance conform to EN 60947-1
Overvoltage level  III
Pollution level 2
Protection level  IP20
Insulation strength  1500V AC, 1 minute
Rated insulation voltage  250V AC
Rated impulse voltage  6000V(1.2/50us)

 

External dimensions

PH6404-2A2B.png

Functional Block Diagram

PH6404-2A2B(1).png

Typical application

PH6404-2A2B(2).png

Wiring diagram

(1) The instrument wiring adopts Pluggable connecting terminal ;
(2) The soft copper cross-sectional area of the input side wire must be greater than 0.5mm2, and the output side must be greater than 1mm2;
(3) The exposed length of the wire is about 8mm, which is locked by M3 screws;
(4) The output contacts must provide enough fuse protection connections;
(5) Copper conductor must withstand an ambient temperature of at least 75 ℃; 
(6) Terminal screws can cause misoperation, heating, etc. Therefore, please tighten it according to the specified torque. Terminal screw tightening torque 0.5Nm.

接线.png

Installation

Safety relays should be installed in control cabinets with at least IP54 protection level.Meanwhile, the installation and use should comply with the relevant provisions of GB 5226.1-2019 "Mechanical and Electrical Safety - Mechanical and Electrical Equipment - Part 1: General Technical Conditions".
The PH6404-2A2B series safety relays are all installed with DIN35mm guide rails. Installation steps are as follows
(1) Clamp the upper end of the instrument onto the guide rail;  
(2) Push the lower end of the instrument into the guide rail.

安装.png

Dismantling

Insert a screwdriver (blade width ≤ 6mm) into the metal latch at the lower end of the instrument panel;
Push the screwdriver upwards and pry the metal latch downwards;
Pull the instrument panel up and out of the guide rail.

拆卸.png

Maintenance

(1) Please regularly check whether the safety function of the safety relay is in good condition, and whether there are signs that the circuit or the original is tampered with or bypassed;
(2) Please follow the relevant safety regulations and operate according to the instructions in this instruction manual, otherwise it may lead to fatal accidents or loss of personnel and property;
(3) The products have undergone strict inspection and quality control before leaving the factory. If you find that the products are not working properly and suspect that the internal module is faulty, please contact the nearest agent or directly contact the technical support hotline 400 711 6763.
(4) Within six years from the date of delivery, all product quality problems during normal use shall be repaired by Pinghe free of charge.

 

Attention

Please verify whether the product packaging, product label model, and specifications are consistent with the purchase contract;
Before installing and using safety relays, carefully read this manual;
If you have any questions, please contact the Beijing Pinghe Technical Support Hotline at 400 711 6763;
The safety relay should be installed in a control cabinet with at least IP54 protection level;
Use 220V AC power supply for instrument power supply;

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

return