Overview
RTD signal input, DC signal output, single input and signal output.
Intelligently programmable, the actual measuring range of RTD can be set by computer.
In the "Common models and parameters" the number "8" means "customizable".
Specifications
|
RTD excitation current |
800uA |
|
Load capacity |
Current type load resistance≤500Ω, voltage type load current<5mA |
|
Output accuracy |
0.1%F.S |
|
Temperature drift |
0.005% F.S/℃ |
|
Temperature parameters |
Working temperature: -20℃~+60℃, storage temperature: -40℃~+80℃ |
|
Relative humidity |
10%~95% RH no condensation |
|
Insulation resistance |
Between input and output, between input, output and power supply≥100MΩ (500VDC) |
|
Dielectric strength |
Between input and output, between input, output and power supply≥2000VAC/min |
|
Electromagnetic compatibility |
GB/T 18268(IEC 61326-1) |
|
Power supply |
24VDC±10% |
|
Response time |
<100ms |
|
Power consumption |
Current output<0.8W, voltage output<0.6W |
|
MTBF |
80000(h) |
Dimensions

Schematic diagram and terminal assignments

Note: 1. When it is with three-wire RTD input, it is necessary to ensure that three wires are equal in length as much as possible.
2. When it is with two-wire RTD input, the terminals 2 and 4 must be short-circuited connected.
|
Terminal |
Terminal assignments |
||
|
9 |
Power supply + |
24VDC±10% |
|
|
10 |
Power supply - |
||
|
|
2-wire |
3-wire |
|
|
2 |
Short connected with terminal 4 |
Input- |
RTD signal |
|
3 |
Input+ |
Input+ |
|
|
4 |
Input- |
Input- |
|
|
5 |
Output+ |
DC signal |
|
|
6 |
Output- |
||
Model definition

|
Input signal type and range table |
||||
|
Code |
RTD model |
Measurement range |
Minimum range |
Conversion accuracy |
|
1 |
G53 |
-50~150℃ |
20℃ |
0.2℃/0.1% |
|
2 |
Cu50 |
-50~150℃ |
20℃ |
0.2℃/0.1% |
|
4 |
Pt100 |
-200~850℃ |
20℃ |
0.2℃/0.1% |
|
6 |
Pt1000 |
-200~850℃ |
20℃ |
0.2℃/0.1% |
|
7 |
Ni1000 |
-60~250℃ |
20℃ |
0.2℃/0.1% |
Common models and parameters
|
Model |
Channel numbers |
Input |
Output |
Power supply condition |
|
PHG-11TZ-41 |
1 input 1 output |
Pt100(-200~850℃) |
4~20mA |
24VDC |
|
PHG-11TZ-42 |
1 input 1 output |
Pt100(-200~850℃) |
0~20mA |
24VDC |
|
PHG-11TZ-43 |
1 input 1 output |
Pt100(-200~850℃) |
0~5V |
24VDC |
|
PHG-11TZ-44 |
1 input 1 output |
Pt100(-200~850℃) |
0~10V |
24VDC |
|
PHG-11TZ-45 |
1 input 1 output |
Pt100(-200~850℃) |
1~5V |
24VDC |
|
PHG-11TZ-46 |
1 input 1 output |
Pt100(-200~850℃) |
1:1 |
24VDC |
|
PHG-11TZ-47 |
1 input 1 output |
Pt100(-200~850℃) |
±10V |
24VDC |
|
PHG-11TZ-11 |
1 input 1 output |
G53(-50~150℃) |
4~20mA |
24VDC |
|
PHG-11TZ-21 |
1 input 1 output |
Cu50(-50~150℃) |
4~20mA |
24VDC |
|
PHG-11TZ-61 |
1 input 1 output |
Pt1000(-200~850℃) |
4~20mA |
24VDC |
|
PHG-11TZ-71 |
1 input 1 output |
Ni1000(-60~250℃) |
4~20mA |
24VDC |
|
PHG-11TZ-88 |
1 input 1 output |
Customizable |
Customizable |
24VDC |